Hybrid inverter · 230 Vac · Parallel to 6
VM II 8–11 kW
The larger hybrid inverter, with two PV inputs, up to 150 A of solar charging and parallel operation to six units. Built for sites that outgrew a 5 kW wall unit but do not want a three-phase system.
Two models: VMII-8KW and VMII-11KW, both 48 V battery and parallel capable.
Design highlights
What the bigger chassis buys
Splits the array across two MPPTs up to 11 kW total, so one shaded string does not cost you the whole day's yield.
On the 11 kW model. Enough to refill a large 48 V bank in a single good day without a separate charge controller.
Up to six inverters share the load, which covers small commercial sites without stepping up to three-phase equipment.
Replaceable fan and a built-in anti-dust kit — the two failures that actually happen in dusty installations.
Technical specifications
VM II 8–11 kW
Two models, 48 V battery, parallel capable.
| Parameter | VMII-8KW | VMII-11KW |
|---|---|---|
| Input | ||
| Rated power | 8000 VA / 8000 W | 11000 VA / 11000 W |
| Parallel capability | Yes, up to 6 units | |
| Nominal voltage | 230 Vac | |
| Selectable voltage range | 170–280 Vac (PC mode); 90–280 Vac (appliance mode) | |
| Frequency range | 60/50 Hz, auto sensing | |
| Output | ||
| AC voltage regulation, battery mode | 230 Vac ±5% | |
| Maximum power | 8000 W | 11000 W |
| Peak efficiency | Up to 93% | |
| Transfer time | 10 ms (PC mode); 20 ms (appliance mode) | |
| Waveform | Pure sine wave | |
| No-load consumption | <70 W | <85 W |
| DC output | 12 Vdc ±5%, 100 W | |
| Battery & AC charger | ||
| Battery voltage | 48 Vdc | |
| Floating charge voltage | 54 Vdc | |
| Overcharge protection | 66 Vdc | |
| Maximum charge current | 100 A | 100 A |
| Solar charger | ||
| Maximum PV array power | 8000 W (4000 W × 2) | 11000 W (5500 W × 2) |
| Maximum PV open circuit voltage | 500 Vdc | |
| MPPT operating range | 120–450 Vdc | |
| Maximum solar charging current | 120 A | 150 A |
| Maximum charging current | 120 A | 150 A |
| General | ||
| Dimensions D × W × H | 147.4 × 432.5 × 553.6 mm | |
| Net weight | 18.4 kg | |
| Communication | USB / RS232 / RS485 / WiFi / dry contact | |
| Operating humidity | 5–95% relative, non-condensing | |
| Operating temperature | 0 to 55 °C | |
| Storage temperature | −15 to 60 °C | |
Specifications subject to change without notice. Parallel kits and current-sharing cables are ordered separately. Confirm the battery bank size before paralleling more than three units.
12 months on the UPS unit against manufacturing defects. Wear parts and battery banks are covered by their own terms — ask for the current statement before quoting.
Sizing a hybrid system above 5 kW?
Send the array layout, the battery bank and the peak load. We will confirm whether one 11 kW unit or two 8 kW units in parallel is the better answer.
Related products