Hybrid inverter · Dual MPPT · 48 V battery
SPI Series 8–12 kW
A hybrid inverter for sites that run on solar, battery and a generator at the same time. Dual MPPT, 48 V battery, and split-phase 120/240 V output — the configuration most of Latin America, the Caribbean and North America actually installs.
Three models: SPI-8000W, SPI-10000W and SPI-12000W. Peak power is twice rated for motor starting.
Design highlights
What makes a hybrid inverter useful
Two independent trackers so a shaded array and a clean one do not drag each other down. 125–425 Vdc operating window covers most 8–10 panel strings without a combiner.
One unit delivers both 120 V and 240 V legs, or three-phase when paralleled. That is what split-phase markets install without adding a transformer.
PV plus grid plus generator charging on the 12 kW model. For a site that needs the battery back by morning, charging current is the real bottleneck, not array size.
The generator feeds through the inverter rather than around it, with a 63 A bypass that carries the load when the inverter is out of service.
Six units parallel for larger sites, with three-phase output available from the same platform.
Longer than our UPS line, because the duty cycle is different — this is a warranty set against daily cycling, not standby.
Technical specifications
SPI Series 8–12 kW
Three models, 48 V battery, dual MPPT.
| Parameter | SPI-8000W | SPI-10000W | SPI-12000W |
|---|---|---|---|
| Inverter output | |||
| Rated power | 8000 W | 10000 W | 12000 W |
| Peak power | 16000 W | 20000 W | 24000 W |
| Rated output voltage | 120 Vac single phase / 240 Vac split phase; three phase when paralleled | ||
| Motor load capacity | 5 HP | 6 HP | 6 HP |
| Output frequency | 60/50 Hz, auto sensing | ||
| Waveform | Pure sine wave | ||
| Transfer time | 10 ms typical | ||
| Battery | |||
| Battery type | Lithium / lead acid / user-defined | ||
| Rated battery voltage | 48 Vdc | ||
| Battery voltage range | 40–60 Vdc | ||
| Max PV charging current | 180 A | 200 A | 220 A |
| Max utility / generator charging current | 100 A | 120 A | 140 A |
| Max hybrid charging current | 180 A | 200 A | 220 A |
| PV input | |||
| Number of MPPT | 2 | ||
| Maximum PV array power | 7500 W + 7500 W | 9000 W + 9000 W | 9000 W + 9000 W |
| Max input current | 22 A + 22 A | ||
| Max open circuit voltage | 500 Vdc + 500 Vdc | ||
| MPPT range at operating voltage | 125–425 Vdc | ||
| Utility / generator input | |||
| Input voltage range | 90–275 Vac | ||
| Frequency range | 50/60 Hz | ||
| Bypass overload current | 63 A | ||
| Efficiency | |||
| MPPT tracking efficiency | 99.9% | ||
| Max battery inverter efficiency | 92% | ||
| General | |||
| Parallel capability | 1–6 units | ||
| Dimensions D × W × H | 450 × 620 × 142 mm | ||
| Net weight | 27 kg | ||
| Protection degree | IP20 / IP54 | ||
| Operating temperature | −15 to 55 °C | ||
| Storage temperature | −15 to 60 °C | ||
| Warranty | 3 years | ||
| Communication | |||
| Standard | RS485 / USB / dry contact | ||
| Optional | WiFi / GPRS | ||
Specifications subject to change without notice. Battery banks are not included — the inverter is compatible with lithium, lead acid and user-defined profiles over 40–60 Vdc. IP54 enclosure available on request.
3 years on the SPI hybrid inverter range, against manufacturing defects. Battery banks are supplied separately and carry their own terms.
Designing an off-grid or hybrid site?
Send the daily load in kWh, the array size and the battery you plan to use. We will confirm the model, the string configuration and the parallel arrangement.