Modular UPS · Three phase in / three phase out
RM Series Modular UPS 30–600 kVA
An N+X redundant UPS built from hot-swappable 30 kVA or 50 kVA modules. Capacity is added one module at a time, which means you buy the load you have today and the frame grows with the room.
30 kVA module: 30–300 kVA per frame. 50 kVA module: 50–600 kVA per frame. Up to 4 frames in parallel.
Design highlights
Redundancy you can buy later
A 30 kg module is replaced in minutes without transferring the load to bypass — the main reason modular wins on total cost of ownership.
Fit only the modules the load needs plus one for redundancy. Spare capacity is a purchase decision, not a design constraint.
Three-level conversion with ECO mode, which matters when the UPS runs 8,760 hours a year.
Each kVA delivers a full kW, so a smaller frame does the same work as a conventional 0.9 PF unit.
One central bypass per frame with independent module control — a single module fault does not take the system down.
Compatible with lithium battery systems and managed through RS485, CAN, dry contact or SNMP.
Technical specifications
30 kVA module — RM90-30 / RM150-30 / RM300-30
Frame capacity 30–300 kVA, up to 10 modules.
| Parameter | RM90-30 | RM150-30 | RM300-30 |
|---|---|---|---|
| Capacity | |||
| Cabinet capacity | 30–90 kVA | 30–150 kVA | 30–300 kVA |
| Module capacity | 30 kVA | ||
| Maximum modules | 3 | 5 | 10 |
| Input | |||
| Phase | 3 phase 4 wires + ground | ||
| Rated voltage | 380 / 400 / 415 Vac | ||
| Voltage range | 207–478 Vac | ||
| Frequency range | 40–70 Hz | ||
| Power factor | ≥0.99 | ||
| Current THDi | ≤3% at 100% linear load | ||
| Bypass voltage range | Upper +25%, lower −45% (other settings optional) | ||
| Bypass frequency protection | ±10% | ||
| Generator access | Yes | ||
| Power walk-in | Yes | ||
| Output | |||
| Phase | 3 phase 4 wires + ground | ||
| Rated voltage | 380 / 400 / 415 Vac | ||
| Power factor | 1.0 | ||
| Voltage regulation | ±1% | ||
| Frequency, utility mode | ±1%, ±2%, ±4%, ±5% or ±10% of rated frequency (selectable) | ||
| Frequency, battery mode | (50/60 ±0.1%) Hz | ||
| Crest factor | 3:1 | ||
| THDi | ≤2% linear load, ≤5% non-linear load | ||
| Efficiency | 96% | ||
| Overload | ≤110% to bypass after 60 min; ≤125% after 10 min; ≤150% after 1 min | ||
| Battery | |||
| Voltage | 192 Vdc / ±204 / ±216 / ±228 / ±240 Vdc (32–40 blocks optional) | ||
| Charge current, cabinet | 30 A max | 50 A max | 100 A max |
| Charge current, module | 10 A max | ||
| Transfer time | |||
| Utility to battery | 0 ms | ||
| Utility to bypass | 0 ms | ||
| Communication & environment | |||
| Interface | RS232, RS485, 2 × intelligent slot, dry contact, SNMP | ||
| Operating temperature | 0 to 40 °C | ||
| Storage temperature | −25 to 55 °C | ||
| Humidity | 0–95% non-condensing | ||
| Altitude | <1500 m | ||
| Physical | |||
| Cabinet D × W × H | 850 × 600 × 1350 mm | 850 × 600 × 1350 mm | 1100 × 600 × 2000 mm |
| Module D × W × H | 620 × 440 × 86 mm | ||
| Cabinet weight | 160 kg | 170 kg | 275 kg |
| Module weight | 33.5 kg | ||
| Standards | EN62040-1, EN62040-2 | ||
Specifications subject to change without notice. Cabinet dimensions, noise level and module count for the 400–600 kVA frames vary with the configuration ordered — confirm at tender stage.
Technical specifications
50 kVA module — RM300-50 to RM600-50
Frame capacity 50–600 kVA, up to 12 modules.
| Parameter | RM300-50 | RM400-50 | RM500-50 | RM600-50 |
|---|---|---|---|---|
| Capacity | ||||
| Cabinet capacity | 50–300 kW | 50–400 kW | 50–500 kW | 50–600 kW |
| Module capacity | 50 kW | |||
| Maximum modules | 6 | 8 | 10 | 12 |
| Input | ||||
| Phase | 3 phase 4 wires + ground | |||
| Rated voltage | 380 / 400 / 415 Vac | |||
| Voltage range | 138–485 Vac | |||
| Frequency range | 40–70 Hz | |||
| Power factor | ≥0.99 | |||
| Current THDi | ≤3% at 100% linear load | |||
| Bypass voltage range | Upper +25%, lower −45% (other settings optional) | |||
| Bypass frequency protection | ±10% | |||
| Generator access | Yes | |||
| Power walk-in | Yes | |||
| Output | ||||
| Phase | 3 phase 4 wires + ground | |||
| Rated voltage | 380 / 400 / 415 Vac | |||
| Power factor | 1.0 | |||
| Voltage regulation | ±1% | |||
| Frequency, utility mode | ±1% / ±2% / ±4% / ±5% / ±10% of rated frequency (selectable) | |||
| Frequency, battery mode | (50/60 ±0.1%) Hz | |||
| Crest factor | 3:1 | |||
| THDi | ≤2% linear load, ≤4% non-linear load | |||
| Efficiency | 96% | |||
| Overload | ≤110% to bypass after 60 min; ≤125% after 10 min; ≤150% after 1 min | |||
| Battery | ||||
| Voltage | ±180 / 192 / ±204 / ±216 / ±228 / ±240 / ±252 / ±264 / ±276 / ±288 / ±300 Vdc (30–50 blocks optional) | |||
| Module charge current | 20 A max | |||
| Transfer time | ||||
| Utility to battery | 0 ms | |||
| Utility to bypass | 0 ms | |||
| Communication & environment | ||||
| Interface | CAN, RS485, FE, LBS, parallel card, relay card, SNMP card (optional) | |||
| Operating temperature | 0 to 40 °C | |||
| Storage temperature | −25 to 55 °C | |||
| Humidity | 0–95% non-condensing | |||
| Altitude | <1500 m | |||
| Noise level | <65 dB | <65 dB | <70 dB | <70 dB |
| Physical | ||||
| Cabinet W × D × H | 600 × 850 × 2000 mm | 1200 × 850 × 2000 mm | 1200 × 850 × 2000 mm | 1200 × 850 × 2000 mm |
| Module W × D × H | 440 × 620 × 131 mm | |||
| Cabinet weight | 262 kg | 360 kg | 380 kg | 400 kg |
| Module weight | 33 kg | |||
| Standards | EN62040-1, EN62040-2 | |||
Specifications subject to change without notice. Cabinet dimensions, noise level and module count for the 400–600 kVA frames vary with the configuration ordered — confirm at tender stage.
12 months on the UPS unit against manufacturing defects. Wear parts and battery banks are covered by their own terms — ask for the current statement before quoting.
Planning a modular UPS for a data center?
Tell us the IT load, the redundancy you need (N+1, N+N) and the room's supply. We size the frame and the module count.