Online UPS · Galvanic isolation · 1–3 kVA
PT Series 1–3 kVA ISO
An online UPS with an isolation transformer on the output, built for the loads where neutral-to-earth voltage matters: laboratory instruments, imaging equipment and control systems that misbehave on a shared neutral.
Four models: 1K-ISO, 2K-ISO, 2K-ISO-plus and 3K-ISO. Internal battery with external module (EBM) option.
Design highlights
What galvanic isolation actually fixes
The transformer creates a real neutral reference instead of inheriting whatever the building's earthing happens to be — the usual cause of noise on measurement equipment.
Isolation blocks the common-mode interference that travels along the neutral from other loads on the same distribution board.
True double conversion, 0 ms transfer to battery, 90–285 Vac input window and >0.99 input power factor. The isolation is added, not traded against protection.
17 to 36 kg in a tower chassis, with an external battery module connector for longer runtime.
Technical specifications
PT Series 1–3 kVA ISO
Four models, tower chassis, output isolation.
| Parameter | 1K-ISO | 2K-ISO | 2K-ISO-plus | 3K-ISO |
|---|---|---|---|---|
| Capacity | ||||
| Capacity (VA / W) | 1 kVA / 900 W | 2 kVA / 1.8 kW | 2 kVA / 1.8 kW | 3 kVA / 2.7 kW |
| Topology | Double conversion online with galvanic isolation | |||
| AC mains input | ||||
| Wiring | 1 phase 3 wires (L / N + PE) | |||
| Rated voltage | 208 / 220 / 230 / 240 Vac | |||
| Rated frequency | 50 / 60 Hz | |||
| Voltage range | 90–285 Vac ±5 | |||
| Frequency range | (40–70) ±0.5 Hz | |||
| Input power factor | >0.99 | |||
| Bypass voltage range | 180–265 Vac | |||
| Battery & charger | ||||
| Rated battery voltage | 24 Vdc | 48 Vdc | 72 Vdc | 72 Vdc |
| Battery location | Internal | Internal / EBM | Internal / EBM | Internal / EBM |
| Battery capacity | 12 V / 7 Ah × 2 pcs | 12 V / 7 Ah × 4 pcs | 12 V / 7 Ah × 6 pcs | 12 V / 7 Ah × 6 pcs |
| Backup time at half load | >8 min | |||
| Charging current | 1 A on standard models with internal battery; 5.5 A on long-backup models | |||
| External battery | External battery module (EBM) connector available | |||
| AC output | ||||
| Wiring | 1 phase 3 wires (L / N + PE) | |||
| Output voltage | 208 / 220 / 230 / 240 Vac | |||
| Output frequency | 50/60 Hz ±4 Hz sync mode; 50/60 Hz ±0.1% free run | |||
| Voltage regulation | ±1% | |||
| Waveform | Pure sine wave | |||
| Distortion (THDv) | <2% linear load; <5% non-linear load | |||
| Output power factor | 0.9 | |||
| Overload | 60 s at 105–125%; 60 s at 125–150%; 0.5 s above 150% | |||
| Transfer time | Line to battery 0 ms; inverter to bypass 4 ms | |||
| Interface | ||||
| Display | LCD — input voltage, frequency, load level, operating mode, health status | |||
| Standard interfaces | RS232, USB (emulated serial, non-HID), EPO port, intelligent slot | |||
| Communication cards | Network card (SNMP/TCP-IP, app and web monitoring, server / NAS shutdown); CMC MODBUS card; AS400 relay card | |||
| Environment & physical | ||||
| Operating temperature | −10 to 50 °C | |||
| Chassis | Tower | |||
| Dimensions W × H × L | 400×180×260 mm | 425×190×328 mm | 425×190×328 mm | 425×190×328 mm |
| Weight | 17 kg | 32 kg | 36 kg | 36 kg |
Specifications subject to change without notice. The 2K-ISO-plus adds the external battery module option to the standard 2K-ISO configuration. Isolation is continuous in line, battery and bypass modes.
12 months on the UPS unit against manufacturing defects. Wear parts and battery banks are covered by their own terms — ask for the current statement before quoting.
Protecting instruments that need a clean neutral?
Tell us the equipment and the symptom — noise, drifting readings, unexplained resets. We will tell you whether isolation is the fix or whether the problem is upstream.