SHINPOWIN™ Power Protection Request a quote
SHINPOWIN GT Series 6-20 kVA DP tower online UPS with LCD and castors

Online UPS · Split phase · Galvanic isolation

GT Series 6–20 kVA DP

A tower UPS with an isolation transformer between input and output in every operating mode, and a split-phase output that delivers both 120 V and 240 V legs. Output power factor is 1.0, so 20 kVA gives 20 kW.

6–20 kVACapacity
PF 1.0Output
120/240 VSplit phase
TransformerGalvanic isolation

Six models: GT6K / GT10K with internal battery, GT6KL / GT10KL / GT15K / GT20K for external banks.

Design highlights

Where the transformer earns its weight

Isolation in every mode

Galvanic separation between AC input and output on inverter, line and bypass — not only on battery. That is what removes common-mode noise and creates a true neutral-to-earth reference.

Split-phase output

120 V and 240 V from one unit, for markets that distribute two live legs rather than a single phase plus neutral.

Output power factor 1.0

A 20 kVA frame carries a full 20 kW. Against a 0.9 PF unit that is 2 kW more useful load at the same footprint.

Three-level inverter, >93%

Lower switching loss and a cleaner waveform than a two-level bridge, with the transformer still in the path.

Technical specifications

GT Series 6–20 kVA DP

Six models, tower chassis, split-phase output.

ParameterGT6KGT6KLGT10KGT10KLGT15KGT20K
Capacity
Capacity (VA / W)6 kVA / 6 kW6 kVA / 6 kW10 kVA / 10 kW10 kVA / 10 kW15 kVA / 15 kW20 kVA / 20 kW
TechnologyDouble conversion online, three-level inverter
PhaseSplit phase output
Input
Wiring1 phase 3 wires (L/N+PE) or dual phase 4 wires (L1/N1 + L2/N2 + PE)
Rated voltage208 / 220 / 230 / 240 Vac
Voltage range110–285 Vac ±5
Frequency range40–70 Hz
Input power factor≥0.99
Output
Wiring1 phase 3 wires (L/N+PE) or dual phase 4 wires (L1/N1 + L2/N2) + PE
Output voltageHigh voltage 208 / 220 / 230 / 240 Vac; low voltage 110 / 120 Vac
Output power factor1.0
Voltage regulation±2%
Output frequency50/60 Hz ±4 Hz sync mode; 50/60 Hz ±0.1% free run
WaveformPure sine wave
Distortion<2% linear load; <5% non-linear load
Overload10 min at 105–125%; 60 s at 125–150%; 5 s above 150%
Transfer timeLine mode to battery mode: 0 ms
Efficiency
AC / AC mode>93%
DC / AC mode>91%
Battery & charging
Rated battery voltage192 Vdc192 / 240 Vdc192 Vdc192 / 240 Vdc192 / 240 Vdc192 / 240 Vdc
Battery locationInternalExternalInternalExternalExternalExternal
Battery capacity12 V / 7 Ah × 16 pcsDepends on external bank12 V / 7 Ah × 16 pcsDepends on external bankDepends on external bankDepends on external bank
Backup time at half load>6 minDepends on external bank>6 minDepends on external bankDepends on external bankDepends on external bank
Charging current1 A on internal-battery models; 5.5 A on long-backup models
Interface
DisplayLCD — input voltage, frequency, load level, operating mode, health status
Standard portRS232
Optional cardsSNMP (app / web / PC monitoring, server and NAS shutdown), MODBUS, USB, relay card
Environment & physical
Operating temperature−10 to 50 °C
Relative humidity0–98% non-condensing
Audible noise<55 dB at 1 m
ChassisTower
Dimensions W × D × H327×588×730 mm327×588×730 mm327×588×730 mm327×588×730 mm247×690×576 mm247×690×576 mm
Weight92 kg60 kg98 kg66 kg102 kg102 kg

Specifications subject to change without notice. GT15K and GT20K are supplied without internal batteries; battery configuration is sized per project. Output is split phase — confirm the site's distribution before ordering.

Warranty

12 months on the UPS unit against manufacturing defects. Wear parts and battery banks are covered by their own terms — ask for the current statement before quoting.

Need 120 V and 240 V from one UPS?

Tell us the site voltage, the load split between the two legs and the runtime required. We will confirm the model and the battery bank.

Request a quote

Related products

Other platforms

GT Series · 6–10 kVA

GT Series · 6–10 kVA

Standard tower UPS, 208–240 V output.

View series →
PT Series · 1–3 kVA ISO

PT Series · 1–3 kVA ISO

Small online UPS with output isolation.

View series →
TD Series · 3–40 kVA

TD Series · 3–40 kVA

Low-frequency UPS with isolation transformer.

View series →