Online UPS · Three phase in / three phase out
GP33 Series 10–400 kVA
The workhorse three-phase range: 10 to 400 kVA, built on 6th generation DSP control with distributed active paralleling. No central bypass cabinet needed, which is usually the difference between fitting in a room and rebuilding one.
Two frames: 10–120 kVA in a tower cabinet, 160–400 kVA in a full-height cabinet.
Design highlights
Why distributed paralleling matters
Up to six units run in parallel using distributed active control. That removes the cabinet, the floor space and the single point of failure it represents.
Layered, independently sealed ventilation with redundant fans and conformal-coated boards — built for the workshops and container rooms these units actually go into.
Roughly 10% more real load per kVA than a conventional 0.8 PF unit, which usually means a smaller model at the same load.
Inverter short-circuit current of 1.5×In for five seconds on three phases, 2.9×In on single phase — enough to clear a downstream breaker.
Galvanic separation on the inverter path, with bypass isolation available as an option.
Where the load tolerates a short transfer, ECO takes efficiency past 98% and removes most of the losses at light load.
Technical specifications
GP33 Series 10–120 kVA
Nine models, tower cabinet.
| Parameter | 10 kVA | 15 kVA | 20 kVA | 30 kVA | 40 kVA | 60 kVA | 80 kVA | 100 kVA | 120 kVA |
|---|---|---|---|---|---|---|---|---|---|
| Capacity | |||||||||
| Rated capacity | 10 kVA | 15 kVA | 20 kVA | 30 kVA | 40 kVA | 60 kVA | 80 kVA | 100 kVA | 120 kVA |
| Input | |||||||||
| Voltage | 380/400/415 Vac ±25%, 3 phase + neutral + ground | ||||||||
| Frequency | 50/60 Hz ±10%, auto sensing | ||||||||
| Power factor | ≥0.95 with filter | ||||||||
| Bypass voltage range | ±20% (settable) | ||||||||
| Delayed start of rectifier | 10 s (1–300 s settable) | ||||||||
| Output | |||||||||
| Voltage | 380/400/415 Vac ±1%, 3 phase + neutral + ground | ||||||||
| Frequency | 50/60 Hz ±1%, auto sensing | ||||||||
| Efficiency | Line mode >92%; ECO mode >98% | ||||||||
| Transfer time | 0 ms | ||||||||
| Waveform | Sine wave | ||||||||
| Power factor | 0.9 | ||||||||
| Voltage distortion (THDv) | <2% linear load; <5% non-linear load | ||||||||
| Crest factor | 3:1 | ||||||||
| Technology | True online double conversion, microcontroller controlled | ||||||||
| Overload protection | 100–110%: bypass after 10 min; 110–125%: after 1 min; 125–150%: after 1 s | ||||||||
| Isolation transformer | Inverter mode (bypass mode optional) | ||||||||
| Parallel function | Optional, up to 6 units without a central bypass cabinet | ||||||||
| EMI / EMS | EN62040-2; IEC61000-4-2/-3/-4/-5 | ||||||||
| Battery | |||||||||
| Battery type | VRLA, not included | ||||||||
| DC voltage | 384 Vdc | ||||||||
| Charging current | 0 / 5 / 10 / 15 / 20 / 25 / 30 A, adjustable | ||||||||
| Charging time | 4 hours to 90% | ||||||||
| Battery detection | Self-detect, transfer to battery mode adjustable | ||||||||
| Alarm, protection & interface | |||||||||
| Alarm | Output overload, mains abnormality, UPS failure, battery undervoltage | ||||||||
| Protection | Short circuit, overload, overvoltage, undervoltage, low battery, over temperature, fan failure | ||||||||
| Bypass | Solid state | ||||||||
| EPO | Local and/or remote | ||||||||
| Display | LCD touch screen, with LED diagram | ||||||||
| Communication | RS232 / RS485 / dry contacts (standard); SNMP (optional) | ||||||||
| Environment | |||||||||
| Altitude | ≤1000 m, derating 1% for each additional 100 m | ||||||||
| Temperature & noise | 0 to 40 °C / <60 dB at 1.5 m | ||||||||
| Storage temperature | −25 to 55 °C without batteries | ||||||||
| Protection rating | IP20 | ||||||||
| Humidity | 0–95% non-condensing | ||||||||
| Physical | |||||||||
| Dimensions W × D × H | 300×600×810 mm | 300×600×810 mm | 300×600×810 mm | 400×750×1010 mm | 400×750×1010 mm | 530×890×1320 mm | 530×890×1320 mm | 810×920×1660 mm | 810×920×1660 mm |
| Net weight | 95 kg | 115 kg | 122 kg | 178 kg | 222 kg | 278 kg | 360 kg | 510 kg | 550 kg |
Specifications subject to change without notice. Batteries are not included; battery banks are sized per project. Dimensions are W × D × H and exclude packaging.
Technical specifications
GP33 Series 160–400 kVA
Five models, full-height cabinet.
| Parameter | 160 kVA | 200 kVA | 250 kVA | 300 kVA | 400 kVA |
|---|---|---|---|---|---|
| Capacity | |||||
| Rated power | 160 kVA / 144 kW | 200 kVA / 180 kW | 250 kVA / 225 kW | 300 kVA / 270 kW | 400 kVA / 360 kW |
| Rated input voltage | 380/400/415 Vac, 3 phase 4 wire | ||||
| Rated frequency | 50/60 Hz | ||||
| Input | |||||
| Input voltage range | ±25% | ||||
| Input frequency range | 45–65 Hz | ||||
| Input soft start | 0–100% (5–300 s settable) | ||||
| Input power factor | >0.95 with filter | ||||
| Input harmonic current (THDi) | <4.5% with harmonic filter | ||||
| Bypass | |||||
| Bypass voltage range | −20% to +15% | ||||
| Bypass frequency range | 50/60 Hz ±10% | ||||
| Output | |||||
| Inverter output voltage | 380/400/415 Vac, 3 phase 4 wire | ||||
| Voltage stability | ±1% steady state, ±3% transient | ||||
| Frequency | 50/60 Hz ±1%, auto sensing | ||||
| Mains synchronisation window | ±5% | ||||
| Output power factor | 0.9 | ||||
| Transient response time | <5 ms | ||||
| Overload protection | 100–110%: bypass after 10 min; 110–125%: after 1 min; 125–150%: after 1 s | ||||
| Short-circuit current from inverter | 3 phase 1.5 × In for 5 s; 1 phase 2.9 × In for 5 s | ||||
| DC voltage | 384 Vdc | ||||
| Phase shift at 100% unbalanced load | <1° | ||||
| Total harmonic distortion (THDv) | ≤2% linear load; ≤5% non-linear load | ||||
| System efficiency | Up to 94% (inverter up to 98%) | ||||
| Other parameters | |||||
| Charging current | 0 / 5 / 10 / 15 / 20 / 25 / 30 A, adjustable | ||||
| DC ripple voltage | ≤1% | ||||
| Operating temperature | 0 to 40 °C | ||||
| Relative humidity | 0–95% non-condensing | ||||
| Maximum operating altitude | ≤1000 m; derate 1% per additional 100 m | ||||
| Noise at 1 m | 58–68 dB | ||||
| Protection rating | IP20 | ||||
| Communication | Standard RS232 / RS485; optional SNMP / MODBUS / dry contact | ||||
| Physical | |||||
| Weight | 610 kg | 715 kg | 868 kg | 1260 kg | 1460 kg |
| Dimensions W × D × H | 810×920×1860 mm | 810×920×1860 mm | 810×920×1860 mm | 1150×960×1960 mm | 1320×1220×1960 mm |
Specifications subject to change without notice. Batteries are not included; battery banks are sized per project. Dimensions are W × D × H and exclude packaging.
12 months on the UPS unit against manufacturing defects. Wear parts and battery banks are covered by their own terms — ask for the current statement before quoting.
Comparing GP33 with ST33?
GP33 is the conventional three-phase range; ST33 uses replaceable power modules. Send the load and the room constraints and we will say which one fits.
Related products
Other platforms


RM Series · 30–600 kVA
Modular N+X redundant UPS with hot-swappable 30/50 kVA modules.
View series →