SHINPOWIN™ Power Protection Request a quote
SHINPOWIN VM IV hybrid solar inverter 4-6 kW, angled view with LED ring

Hybrid inverter · 230 Vac · Built-in WiFi

VM IV 4–6 kW

A fourth-generation hybrid inverter for homes and small commercial sites. The practical difference from the earlier VM series is the built-in WiFi, the 4.3-inch colour display and the ability to run with no battery connected at all.

4–6 kWCapacity
500 VdcPV input
100 ACharging
WiFiBuilt in

Two models: VM IV 4000W (24 V battery) and VM IV 6000W (48 V battery).

Design highlights

Built for installers, not catalogues

Runs without a battery

Battery-independent design means the inverter can be commissioned and used as a straight PV inverter, with storage added later.

USB On-the-Go

Firmware updates, parameter rewrites and data downloads from a USB stick — no laptop and no dongle on site.

Built-in WiFi and data logging

Events are stored inside the inverter, so a fault that cleared itself is still visible when you arrive.

Configurable for the load

Input range, charging source priority, charging current and output usage window are all set from the panel, per installation.

Technical specifications

VM IV 4–6 kW

Two models, 230 Vac single phase.

ParameterVM IV 4000WVM IV 6000W
Input
Rated power4000 VA / 4000 W6000 VA / 6000 W
Nominal voltage230 Vac
Low loss voltage170 ±7 Vac (UPS mode); 90 ±7 Vac (appliance mode)
Low loss return voltage180 ±7 Vac (UPS); 100 ±7 Vac (appliance)
High loss voltage280 ±7 Vac
High loss return voltage270 ±7 Vac
Maximum AC input voltage300 Vac
Nominal input frequency60/50 Hz, auto sensing
Low loss frequency40 ±1 Hz; return at 42 ±1 Hz
High loss frequency65 ±1 Hz; return at 63 ±1 Hz
Output short-circuit protectionCircuit breaker
Inverter output
Efficiency in line mode>95% at rated resistive load, battery fully charged
Transfer time10 ms typical (UPS mode); 20 ms typical (appliance mode)
Output voltage regulation230 Vac ±5%
Output frequency50/60 Hz ±1%
Peak efficiency94%
Overload protection5 s at ≥110% load; 10 s at 105–110%
Surge capacity2 × rated power for 5 s
Battery
Nominal DC input voltage24 Vdc48 Vdc
Cold start voltage23 Vdc46 Vdc
Low DC cut-off21 Vdc42 Vdc
High DC cut-off33 Vdc63 Vdc
No-load consumption<40 W<55 W
Charging
Charging algorithm3-step
Maximum charging current100 A
Bulk charging voltage29.2 V flooded / 28.2 V AGM-GEL58.4 V flooded / 56.4 V AGM-GEL
Floating charge voltage27 Vdc54 Vdc
MPPT solar charger
Maximum PV array power5000 W6000 W
Maximum PV current27 A
Nominal PV voltage320 Vdc360 Vdc
MPPT operating range60–450 Vdc
Maximum PV open circuit voltage500 Vdc
Maximum charging current120 A
General
Communication portRS232 / USB / BMS (RS485, CAN-BUS or RS232)
Operating humidity5–95% relative, non-condensing
Operating temperature0 to 55 °C
Storage temperature−15 to 60 °C
Net weight10 kg12 kg

Specifications subject to change without notice. Loss and return voltages are configurable from the LCD panel. Battery type profiles cover flooded, AGM and GEL lead acid.

Warranty

12 months on the UPS unit against manufacturing defects. Wear parts and battery banks are covered by their own terms — ask for the current statement before quoting.

Specifying storage for a house or small site?

Send the daily consumption, the array size and whether a generator is involved. We will confirm the model and the battery configuration.

Request a quote

Related products

Other platforms

VM II 8–11 kW

VM II 8–11 kW

Larger hybrid inverter with 6-unit paralleling.

View series →
SPI Series · 8–12 kW

SPI Series · 8–12 kW

Split-phase 120/240 V hybrid inverter.

View series →
HV Stack battery · 80–241 kWh

HV Stack battery · 80–241 kWh

LiFePO4 storage from 80 to 241 kWh.

View series →