SHINPOWIN™ Power Protection Request a quote
RT Series Rack-Tower Convertible UPS 1–10 kVA

Online UPS · Rack or tower, one chassis

RT Series 1–10 kVA

One chassis, two mounting options: 2U to 5U in a rack, or stood upright as a tower with the feet supplied. Output power factor is 1.0, so a 6 kVA model delivers 6 kW rather than 5.4 kW.

1–10 kVACapacity
PF 1.0Output power factor
90–300 VacInput window
2U–5URack height

Four models at 1–3 kVA and four at 6–10 kVA. KL models take an external battery bank.

Design highlights

Convertible, and honest about what that buys you

Rack or tower, same unit

Convert the front panel and fit the supplied feet to stand it on a floor; add ears to slide it into 19-inch rails. One SKU covers both deployments, which halves the stock a distributor has to carry.

Output power factor 1.0

A 6 kVA RT gives 6 kW. Against a 0.9 PF unit that is 600 W of extra usable load — often the difference between one model and the next size up.

90–300 Vac input

The widest window in our single-phase range. Industrial sites with heavy motor load see sustained undervoltage; this unit rides it out on mains.

CVCF mode

Constant voltage and constant frequency output for sensitive instrumentation that cannot follow a wandering mains frequency.

Conformal-coated boards

FR4 double-sided PCBs with conformal coating — for humid, dusty or coastal installations where uncoated boards corrode.

Monitoring as standard

RS232, USB, EPO and an intelligent card slot are standard; MODBUS, RS485, SNMP and AS400 cards are optional.

Technical specifications

RT Series 1–3 kVA

Six models, 2U rack-tower convertible.

ParameterRT1KRT1KLRT2KRT2KLRT3KRT3KL
Capacity
Capacity (VA / W)1 kVA / 1000 W1 kVA / 1000 W2 kVA / 2000 W2 kVA / 2000 W3 kVA / 3000 W3 kVA / 3000 W
TechnologyDouble conversion online, 3-level inverter
Phase1 phase in / 1 phase out
Input
WiringL / N + PE
Rated voltage208 / 220 / 230 / 240 Vac
Voltage range90–300 Vac
Frequency range40–70 Hz
Input power factor≥0.99
Output
WiringL / N + PE
Output voltage208 / 220 / 230 / 240 Vac
Output power factor1.0
Voltage regulation±1%
Output frequency50/60 Hz ±4 Hz sync mode; 50/60 Hz ±0.1% free run
WaveformPure sine wave
Distortion<2% linear load; <5% non-linear load
Overload1 min at 105–130%; 10 s at 131–150%; 0.5 s above 150%
Efficiency
AC / AC mode89%89%90%90%90%90%
DC / AC mode87%87%88%88%88%88%
Battery
Rated battery voltage24 Vdc36 Vdc48 Vdc72 Vdc72 Vdc72 Vdc
Battery locationInternalExternalInternalExternalInternalExternal
Battery capacity12 V / 7 Ah × 2 pcsDepends on external bank12 V / 7 Ah × 4 pcsDepends on external bank12 V / 7 Ah × 6 pcsDepends on external bank
Backup time at half load>6 minDepends on external bank>6 minDepends on external bank>6 minDepends on external bank
Charging current1 A internal4 A long backup1 A internal4 A long backup1 A internal4 A long backup
Interface
DisplayLCD — input voltage, frequency, load level, operating mode, health status
Standard portsRS232, USB, EPO, intelligent card slot
Optional cardsMODBUS, RS485, SNMP, AS400
Environment & physical
Operating temperature−10 to 50 °C
Relative humidity0–98% non-condensing
Audible noise<55 dB at 1 m
ChassisRack-tower convertible, 2U
DimensionsRT1K(L) / RT2K(L) / RT3KL: 440 × 88 (2U) × 428 mm. RT3K: 438 × 88 (2U) × 588 mm including internal battery
Weight11.3 kg7.2 kg15.9 kg7.9 kg22.7 kg8.7 kg

Specifications subject to change without notice. Internal-battery models (K) and long-backup models (KL) use the same chassis; KL units are supplied without batteries and are sized for an external bank.

Technical specifications

RT Series 6–10 kVA

Four models, 3U to 5U with internal batteries.

ParameterRT6KRT6KLRT10KRT10KL
Capacity
Capacity (VA / W)6 kVA / 6000 W6 kVA / 6000 W10 kVA / 10000 W10 kVA / 10000 W
TechnologyDouble conversion online, 3-level inverter
Phase1 phase in / 1 phase out
Input
WiringL / N + PE
Rated voltage208 / 220 / 230 / 240 Vac
Voltage rangeL–N: 90–300 Vac
Frequency range40–70 Hz
Input power factor≥0.99
Output
WiringL / N + PE
Output voltage208 / 220 / 230 / 240 Vac
Output power factor1.0
Voltage regulation±1%
Output frequency50/60 Hz ±4 Hz sync mode; 50/60 Hz ±0.1% free run
WaveformPure sine wave
Distortion<2% linear load; <5% non-linear load
Overload1 min at 105–125%; 30 s at 125–150%; 0.5 s above 150%
Efficiency
AC / AC mode>93%>93%>94%>94%
DC / AC mode>91%>91%>92%>92%
Battery
Rated battery voltage144 Vdc192 or 240 Vdc192 Vdc192 or 240 Vdc
Battery typeInternal 9 AhExternal, dependsInternal 9 AhExternal, depends
Backup time at full load3 minDepends on external bank1 minDepends on external bank
Charging current2 A / 4 A selectable4 A2 A / 4 A selectable4 A
Interface
DisplayLCD — input voltage, frequency, load level, operating mode, health status
Standard portsRS232, USB, EPO, intelligent card slot
Optional cardsMODBUS, RS485, SNMP, AS400
Environment & physical
Operating temperature−10 to 50 °C
Relative humidity0–98% non-condensing
Audible noise<55 dB at 1 m
ChassisRack-tower convertible
DimensionsRT6K: 440 × 132 (3U) × 720 mm. RT10K: 440 × 220 (5U) × 640 mm. RT6KL / RT10KL: 440 × 88 (2U) × 521 mm
Weight51.2 kg10.8 kg68.5 kg12.6 kg

Specifications subject to change without notice. Internal-battery models (K) and long-backup models (KL) use the same chassis; KL units are supplied without batteries and are sized for an external bank.

Warranty

12 months on the UPS unit against manufacturing defects. Wear parts and battery banks are covered by their own terms — ask for the current statement before quoting.

Stocking one SKU for two mounting types

RT models cover both rack and tower deployments. Ask for the rack ear and feet kit list, and for the private-label options if you sell under your own brand.

Request a quote

Related products

Other platforms

SR Series · 1–20 kVA

SR Series · 1–20 kVA

Rack-mounted double-conversion UPS, 2U to 4U.

View series →
GT Series · 1–3 kVA 110 V

GT Series · 1–3 kVA 110 V

Tower UPS for 110/115/120/127 V grids.

View series →
GT Series · 6–10 kVA

GT Series · 6–10 kVA

Single-phase tower UPS, 120-275 Vac input.

View series →