Online UPS · Three phase in / three phase out
ST33 Series 10–40 kVA
The compact end of the ST33 range: 10 to 40 kVA in a tower chassis, with built-in batteries on the 10–20 kVA models. The output configuration is switchable between 380/400/415 V and 208/220 V three-phase from the control programme.
Six models: 10KS / 10K / 20KS / 20K / 30KS / 40KS. At 208/220 V the rating halves — see the two capacity rows in the table.
Design highlights
One chassis, two output voltages
The control programme changes the output configuration to three-phase 208/220 V for sites without a 380 V distribution. The same unit covers both, which matters for mixed-standard markets.
Be clear about this when quoting: the 20 kVA model is 20 kVA at 380/400/415 V and 10 kVA at 208/220 V. The table lists both so nobody is surprised at commissioning.
10 and 20 kVA models ship with internal batteries — install and run, no separate battery room. 30 and 40 kVA use external banks.
Redundancy without a separate parallel cabinet, up to three units sharing the load.
The output accepts unbalanced single-phase loading while the input stays balanced across the three phases.
The range is built around the smallest practical tower footprint, with a visualised LCD as standard and a touch screen as an option.
Technical specifications
ST33 Series 10–40 kVA
Six models, three-phase in and out, two output voltage configurations.
| Parameter | ST33 10KS | ST33 10K | ST33 20KS | ST33 20K | ST33 30KS | ST33 40KS |
|---|---|---|---|---|---|---|
| Capacity | ||||||
| Capacity at 380/400/415 Vac | 10 kVA | 10 kVA | 20 kVA | 20 kVA | 30 kVA | 40 kVA |
| Capacity at 208/220 Vac | 5 kVA | 5 kVA | 10 kVA | 10 kVA | 15 kVA | 20 kVA |
| Input | ||||||
| Phase | 3 phase 4 wires + ground | |||||
| Rated voltage | 380 / 400 / 415 Vac; 208 / 220 Vac | |||||
| Operating voltage range | 207–475 Vac at 380 V; 104–286 Vac at 208 V | |||||
| Operating frequency range | 40–70 Hz | |||||
| Power factor | ≥0.99 | |||||
| Harmonic distortion (THDi) | ≤3% at 100% non-linear load | |||||
| Bypass voltage range | 173–500 Vac at 380 V; 88–286 Vac at 208 V | |||||
| Bypass frequency protection | ±10% | |||||
| Generator input | Supported | |||||
| Output | ||||||
| Phase | 3 phase 4 wires + ground | |||||
| Output voltage | 380 / 400 / 415 Vac or 208 / 220 Vac, ±1% | |||||
| Rated current at 380 V | 15 A | 15 A | 30 A | 30 A | 45 A | 61 A |
| Rated current at 208 V | 13 A | 13 A | 26 A | 26 A | 39 A | 52 A |
| Power factor | 0.9 | |||||
| Voltage regulation | ±1% | |||||
| Output frequency | Utility: 50 Hz (46–54 Hz) / 60 Hz (56–64 Hz); battery: (50/60 ±0.1%) Hz | |||||
| Crest factor | 3:1 | |||||
| Harmonic wave | ≤3% at full resistive load | |||||
| Efficiency | >92% | |||||
| Overload | 105–125% for under 1 min; 125–150% for under 30 s; above 150% for under 300 ms | |||||
| Battery | ||||||
| Battery voltage | 192 / 240 Vdc | 192 / 240 Vdc | 192 / 240 Vdc | 192 / 240 Vdc | ±192 Vdc | ±192 Vdc |
| Number of blocks | 16 / 20 pcs | 16 / 20 pcs | 16 / 20 pcs | 16 / 20 pcs | 32 pcs | 32 pcs |
| Charge current | 5.5 A | 1 A | 7.5 A | 1 A | 5.5 A | 5.5 A |
| Transfer time | ||||||
| Utility to battery | 0 ms | |||||
| Utility to bypass | 0 ms | |||||
| Environment | ||||||
| Operating temperature | 0 to 40 °C | |||||
| Storage temperature | −25 to 55 °C, no battery | |||||
| Humidity | 0–95% non-condensing | |||||
| Altitude | <1500 m | |||||
| Noise level | <60 dB | |||||
| Protection & communication | ||||||
| Alarm | Overload, utility abnormal, UPS fault, battery low | |||||
| Protection | Short circuit, overload, over temperature, battery low, fan fault | |||||
| Communication | RS232 / USB / relay card / SNMP (optional); parallel function (optional) | |||||
| Standards | EN62040-1, EN62040-2 | |||||
| Physical | ||||||
| Dimensions D × W × H | 533×260×501 mm | 560×260×717 mm | 710×260×717 mm | 710×260×717 mm | 710×260×717 mm | 710×260×717 mm |
| Net weight | 26 kg | 72 kg | 57.5 kg | 98 kg | 58.5 kg | 62 kg |
Specifications subject to change without notice. Capacity, rated current and input voltage range depend on the output configuration selected — confirm 380 V or 208 V at the ordering stage. For 60 kVA and above see the ST33 60–160 kVA range.
12 months on the UPS unit against manufacturing defects. Wear parts and battery banks are covered by their own terms — ask for the current statement before quoting.
Need 208 V three-phase from a 10–40 kVA UPS?
Tell us the site voltage and the load per phase. We will confirm the model, the output configuration and whether internal battery is enough for the runtime.