Online UPS · Rack-mounted 2U to 4U
Rack-mounted double-conversion UPS for server rooms and network cabinets. A 90–285 Vac input window on the 1–3 kVA models means it rides through the dips that trip lesser units — without cycling the battery.
Six models at 1–3 kVA and five at 6–20 kVA, including three-phase input versions.
Design highlights
Fits a standard 19-inch cabinet with rear cabling. The 1–3 kVA frame is 360 mm deep, which matters in shallow wall racks.
One of the widest windows in this class — the UPS stays on mains through sags that would push a narrower unit onto battery.
SR31 models take 380/400/415 Vac three-phase input and deliver single-phase output, for racks fed from a three-phase distribution board.
50 Hz in, 60 Hz out or the reverse — useful for equipment imported from another market.
Adjustable input range and a configurable walk-in let it run behind a small generator without overload tripping.
RS232 standard; SNMP, MODBUS, USB and relay cards optional, with server and NAS shutdown support.
Technical specifications
Six models, 2U rack, internal or external battery.
| Parameter | SR1K | SR1KL | SR2K | SR2KL | SR3K | SR3KL |
|---|---|---|---|---|---|---|
| Capacity | ||||||
| Capacity (VA / W) | 1 kVA / 900 W | 1 kVA / 900 W | 2 kVA / 1.8 kW | 2 kVA / 1.8 kW | 3 kVA / 2.7 kW | 3 kVA / 2.7 kW |
| Technology | Double conversion online | |||||
| Phase | 1 phase in / 1 phase out | |||||
| Input | ||||||
| Wiring | L / N + PE | |||||
| Rated voltage | 208 / 220 / 230 / 240 Vac | |||||
| Voltage range | 90–285 Vac | |||||
| Frequency range | 40–70 Hz | |||||
| Input power factor | ≥0.99 | |||||
| Output | ||||||
| Wiring | L / N + PE | |||||
| Output voltage | 208 / 220 / 230 / 240 Vac | |||||
| Output power factor | 0.9 (1.0 optional) | |||||
| Voltage regulation | ±1% | |||||
| Output frequency | 50/60 Hz ±4 Hz sync mode; 50/60 Hz ±0.1% free run | |||||
| Waveform | Pure sine wave | |||||
| Distortion | <2% linear load; <5% non-linear load | |||||
| Overload | 1 min at 105–125%; 30 s at 125–150%; 0.5 s above 150% | |||||
| Efficiency | ||||||
| AC / AC mode | 88% | 88% | 89% | 89% | 90% | 90% |
| DC / AC mode | 86% | 86% | 87% | 87% | 88% | 88% |
| Battery | ||||||
| Rated battery voltage | 24 Vdc | 36 Vdc | 48 Vdc | 72 Vdc | 72 Vdc | 96 Vdc |
| Battery location | Internal | External | Internal | External | Internal | External |
| Battery capacity | 12 V / 7 Ah × 2 pcs | Depends on external bank | 12 V / 7 Ah × 4 pcs | Depends on external bank | 12 V / 7 Ah × 6 pcs | Depends on external bank |
| Backup time at half load | >6 min | Depends on external bank | >6 min | Depends on external bank | >6 min | Depends on external bank |
| Charging current | 1 A on standard models with internal battery; 5.5 A on long-backup models | |||||
| Interface | ||||||
| Display | LCD — input voltage, frequency, load level, operating mode, health status | |||||
| Standard port | RS232 | |||||
| Optional cards | SNMP (remote monitoring via app, web page or PC software; server / NAS shutdown), MODBUS, USB, relay card assembled per order | |||||
| Environment & physical | ||||||
| Operating temperature | −10 to 50 °C | |||||
| Relative humidity | 0–98% non-condensing | |||||
| Audible noise | <55 dB at 1 m | |||||
| Chassis | Rack mount, 2U | |||||
| Dimensions | SR1K / SR1KL / SR2K / SR2KL / SR3KL: 438 × 88 (2U) × 360 mm. SR3K: 438 × 88 (2U) × 500 mm including internal battery | |||||
| Weight | 13 kg | 8.5 kg | 18.5 kg | 11.5 kg | 21.9 kg | 12 kg |
Specifications subject to change without notice. KL models are long-backup units supplied without internal batteries; runtime is configured per project.
Technical specifications
Five long-backup models, 2U to 4U, three-phase input at 10–20 kVA.
| Parameter | SR6KL | SR10KL | SR3110KL | SR3115KL | SR3120KL |
|---|---|---|---|---|---|
| Capacity | |||||
| Capacity (VA / W) | 6 kVA / 5.4 kW | 10 kVA / 9 kW | 10 kVA / 9 kW | 15 kVA / 13.5 kW | 20 kVA / 18 kW |
| Technology | Double conversion online | ||||
| Phase | 1 phase in / 1 phase out | 1 phase in / 1 phase out | 3 phase in / 1 phase out | 3 phase in / 1 phase out | 3 phase in / 1 phase out |
| Input | |||||
| Wiring | L / N + PE | L / N + PE | 3 phase (L1, L2, L3, N) + PE | 3 phase (L1, L2, L3, N) + PE | 3 phase (L1, L2, L3, N) + PE |
| Rated voltage | 208 / 220 / 230 / 240 Vac | 208 / 220 / 230 / 240 Vac | 380 / 400 / 415 Vac | 380 / 400 / 415 Vac | 380 / 400 / 415 Vac |
| Voltage range | L–N: 120–275 Vac | L–N: 120–275 Vac | L–L: 207–475 Vac | L–L: 207–475 Vac | L–L: 207–475 Vac |
| Frequency range | 40–70 Hz | ||||
| Input power factor | ≥0.99 | ||||
| Output | |||||
| Wiring | L / N + PE | ||||
| Output voltage | 208 / 220 / 230 / 240 Vac | ||||
| Output power factor | 0.9 (1.0 optional) | ||||
| Voltage regulation | ±1% | ||||
| Output frequency | 50/60 Hz ±4 Hz sync mode; 50/60 Hz ±0.1% free run | ||||
| Waveform | Pure sine wave | ||||
| Distortion | <2% linear load; <5% non-linear load | ||||
| Overload | 1 min at 105–125%; 30 s at 125–150%; 0.5 s above 150% | ||||
| Efficiency | |||||
| AC / AC mode | >93% | >93% | >94% | >94% | >94% |
| DC / AC mode | >91% | >91% | >92% | >92% | >92% |
| Battery | |||||
| Rated battery voltage | 192 / 240 Vdc, external battery | ||||
| Battery capacity | Depends on the external bank configured for the runtime required | ||||
| Charging current | 5.5 A on long-backup models | ||||
| Interface | |||||
| Display | LCD — input voltage, frequency, load level, operating mode, health status | ||||
| Standard port | RS232 | ||||
| Optional cards | SNMP, MODBUS, USB, relay card | ||||
| Environment & physical | |||||
| Operating temperature | −10 to 50 °C | ||||
| Relative humidity | 0–98% non-condensing | ||||
| Audible noise | <55 dB at 1 m | ||||
| Chassis | Rack mount | ||||
| Dimensions | SR6KL / SR10KL: 438 × 88 (2U) × 500 mm. SR31 10KL: 438 × 132 (3U) × 500 mm. SR31 15KL / 20KL: 438 × 176 (4U) × 530 mm | ||||
| Weight | 14.6 kg | 15 kg | 18.5 kg | 25.6 kg | 26.1 kg |
Specifications subject to change without notice. KL models are long-backup units supplied without internal batteries; runtime is configured per project.
12 months on the UPS unit against manufacturing defects. Wear parts and battery banks are covered by their own terms — ask for the current statement before quoting.
Send the rack depth, the rail kit you use and the load. We will confirm the U height and whether the rear clearance works before you order.