LiFePO4
LV Series 51.2 V battery
51.2 V, 100–314 Ah, wall-mounted at 5 and 10 kWh, floor-standing at 16 kWh, up to 15 in parallel.
LiFePO4 storage
Two architectures, one chemistry: 51.2 V modules that bolt onto a 48 V inverter with no high-voltage cabinet, and a high-voltage stack that scales to 241 kWh behind a single BMS. Both LiFePO4, both shipped with the transport documentation a forwarder will ask for.
Platforms
Every platform below has a full specification table — including models that are not in the brochure.

LiFePO4
51.2 V, 100–314 Ah, wall-mounted at 5 and 10 kWh, floor-standing at 16 kWh, up to 15 in parallel.

Battery system
80–241 kWh in seven capacities on one platform, 256–768 Vdc, 314 Ah modules, 6000 cycles at 80% DoD.
What you are paying for
The LV Series needs no high-voltage cabinet and no separate BMS: it is a 51.2 V block that talks RS485 or CAN to the inverter and parallels to fifteen units. The HV Stack puts 256–768 Vdc behind one BMS when the bank is large enough that cable losses and cabinet space start to matter.
LiFePO4, with UN38.3 test summaries and MSDS on file for every model. Ask for them before your forwarder does — a battery that cannot be documented is a container that does not move.
A UPS holds the load for the seconds it takes a generator to start; a battery bank holds it for hours. Sizing is arithmetic: load in kW, minutes required, depth of discharge allowed, and the efficiency of the inverter in front of it.
Selection
Written the way a quote request usually arrives: a load, a room and a voltage.
| If the requirement is | Architecture | Range |
|---|---|---|
| Retrofit onto an existing 48 V inverter | 51.2 V module, wall or floor | LV 5 / 10 / 16 kWh |
| 15 units in parallel for a small micro-grid | 51.2 V, RS485 / CAN | LV, up to 15 units |
| A commercial bank of 80–241 kWh | High voltage stack, one BMS | HV Stack |
| Runtime measured in hours, not minutes | Bank sized to kWh, not kVA | Either, sized to load |
| Shipment by sea or air | UN38.3 + MSDS per model | Both ranges |
Cycle life and warranty differ by range: the HV Stack is rated 6000 cycles at 80% depth of discharge with a 5-year warranty; the LV modules are rated ≥4000 cycles.
Also relevant
Sizing questions that come up before every order are answered on the selection FAQ — kVA versus kW, runtime arithmetic, 50/60 Hz and non-standard voltages.
Send the load in kW, the hours of autonomy and the inverter you are using. We will return a bank size and the transport documents.