SHINPOWIN™Power Protection Request a quote

LiFePO4 storage

LiFePO4 battery storage, 5–241 kWh

Two architectures, one chemistry: 51.2 V modules that bolt onto a 48 V inverter with no high-voltage cabinet, and a high-voltage stack that scales to 241 kWh behind a single BMS. Both LiFePO4, both shipped with the transport documentation a forwarder will ask for.

2Ranges
5–241 kWhCapacity
≥4000Cycles
15Units in parallel

Platforms

2 platforms in this range

Every platform below has a full specification table — including models that are not in the brochure.

LV Series 51.2 V LiFePO4 Battery 5–16 kWh

LiFePO4

LV Series 51.2 V battery

51.2 V, 100–314 Ah, wall-mounted at 5 and 10 kWh, floor-standing at 16 kWh, up to 15 in parallel.

51.2 V100–314 Ah15 units
View series →
High Voltage Stack Battery System 80–241 kWh

Battery system

High Voltage Stack 80–241 kWh

80–241 kWh in seven capacities on one platform, 256–768 Vdc, 314 Ah modules, 6000 cycles at 80% DoD.

80–241 kWh256–768 VdcLiFePO4
View series →

What you are paying for

Three differences that decide the quote

Low voltage for retrofit, high voltage for new builds

The LV Series needs no high-voltage cabinet and no separate BMS: it is a 51.2 V block that talks RS485 or CAN to the inverter and parallels to fifteen units. The HV Stack puts 256–768 Vdc behind one BMS when the bank is large enough that cable losses and cabinet space start to matter.

Chemistry you can actually ship

LiFePO4, with UN38.3 test summaries and MSDS on file for every model. Ask for them before your forwarder does — a battery that cannot be documented is a container that does not move.

Runtime is a bank size, not a UPS feature

A UPS holds the load for the seconds it takes a generator to start; a battery bank holds it for hours. Sizing is arithmetic: load in kW, minutes required, depth of discharge allowed, and the efficiency of the inverter in front of it.

Selection

Which one fits the site

Written the way a quote request usually arrives: a load, a room and a voltage.

If the requirement isArchitectureRange
Retrofit onto an existing 48 V inverter51.2 V module, wall or floorLV 5 / 10 / 16 kWh
15 units in parallel for a small micro-grid51.2 V, RS485 / CANLV, up to 15 units
A commercial bank of 80–241 kWhHigh voltage stack, one BMSHV Stack
Runtime measured in hours, not minutesBank sized to kWh, not kVAEither, sized to load
Shipment by sea or airUN38.3 + MSDS per modelBoth ranges

Cycle life and warranty differ by range: the HV Stack is rated 6000 cycles at 80% depth of discharge with a 5-year warranty; the LV modules are rated ≥4000 cycles.

Also relevant

Adjacent ranges

Sizing questions that come up before every order are answered on the selection FAQ — kVA versus kW, runtime arithmetic, 50/60 Hz and non-standard voltages.

Need a bank sized to a load profile?

Send the load in kW, the hours of autonomy and the inverter you are using. We will return a bank size and the transport documents.

Talk to an engineer